Fluorescence Quantitation
  1. Quantum™ Alexa Fluor® 488 MESF | Polysciences, Inc.

    Quantitative MESF Kits consist of a series of reference microbead standards whose intensities have been calibrated in Molecules of Equivalent Soluble Fluorochrome (MESF) units. Our FREE Flow Cytometry Data Analysis template, QuickCal®, works with all Quantum™ MESF Kits (access QuickCal® by visiting www.bangslabs.com/products/quickcal and entering the Access Number provided with your standards).

  2. Quantum™ FITC-5 MESF | Polysciences Inc.
    Quantum™ FITC-5 MESF
    Catalog Number BLI555

    Quantum™ FITC-5 MESF kits include six microsphere populations that are ~7-9µm in diameter: one blank and five labeled with increasing amounts of fluorochrome. The assignment of fluorescence intensity in MESF units is performed through direct comparison of fluorescence measurements from solutions of the pure fluorochrome with those from microspheres surface-labeled with the same fluorochrome. In addition to quantitative fluorescence cytometry, Quantum™ MESF kits may be used to assess the detection threshold, resolution, and linearity of the instrument. QuickCal® is provided with each kit to aid in determining the expression level of cells, and for evaluating instrument linearity and detection threshold.

  3. Quantum™ FITC-5 MESF (Premix) | Polysciences, Inc.
    Quantum™ FITC-5 MESF (Premix)
    Catalog Number BLI555P

    Quantum™ FITC-5 MESF kits include six microsphere populations that are ~7-9µm in diameter: one blank and five labeled with increasing amounts of fluorochrome. The assignment of fluorescence intensity in MESF units is performed through direct comparison of fluorescence measurements from solutions of the pure fluorochrome with those from microspheres surface-labeled with the same fluorochrome. In addition to quantitative fluorescence cytometry, Quantum™ MESF kits may be used to assess the detection threshold, resolution, and linearity of the instrument. QuickCal® is provided with each kit to aid in determining the expression level of cells, and for evaluating instrument linearity and detection threshold.

  4. Simply Cellular® anti-Mouse IgG

    Antibody Binding Standards are particles which have ligands covalently linked to their surfaces to bind specific proteins (e.g. Mouse IgG antibodies) in calibrated quantities.

    A test requires one drop (50μl) of particle suspension, which is equivalent to ~100,000 particles. Bangs Flow Cytometry Standards are 7-9μm in diameter (unless otherwise noted) to approximate the size of human lymphocytes.

  5. Simply Cellular® anti-Human IgG

    Antibody Binding Standards are particles which have ligands covalently linked to their surfaces to bind specific proteins (e.g. Human IgG antibodies) in calibrated quantities.

    A test requires one drop (50μl) of particle suspension, which is equivalent to ~100,000 particles. Bangs Flow Cytometry Standards are 7-9μm in diameter (unless otherwise noted) to approximate the size of human lymphocytes.

  6. Simply Cellular® anti-Rat IgG

    Antibody Binding Standards are particles which have ligands covalently linked to their surfaces to bind specific proteins (e.g. Human IgG antibodies) in calibrated quantities.

    A test requires one drop (50μl) of particle suspension, which is equivalent to ~100,000 particles. Bangs Flow Cytometry Standards are 7-9μm in diameter (unless otherwise noted) to approximate the size of human lymphocytes.

  7. Quantum™ Simply Cellular® anti-Human IgG | Polysciences, Inc.

    Quantum™ Simply Cellular® Kits contain a mixture of microbeads which bind specific amounts of IgG antibodies. These standards are calibrated in terms of Antibody Binding Capacity (ABC) and can be used to construct calibration plots to determine the ABC of unknown samples and monitor instrument performance. Our FREE Flow Cytometry Data Analysis template, QuickCal®, is designed to work with all Quantum™ Simply Cellular® Kits (access QuickCal® by visiting www.bangslabs.com/products/quickcal and entering the Access Number provided with your standards).

    A test requires one drop (50μl) of particle suspension, which is equivalent to ~100,000 particles. Bangs Flow Cytometry Standards are 7-9μm in diameter (unless otherwise noted) to approximate the size of human lymphocytes.

  8. Quantum™ Simply Cellular® anti-Rat IgG | Polysciences, Inc.

    Quantum™ Simply Cellular® Kits contain a mixture of microbeads which bind specific amounts of IgG antibodies. These standards are calibrated in terms of Antibody Binding Capacity (ABC) and can be used to construct calibration plots to determine the ABC of unknown samples and monitor instrument performance. Our FREE Flow Cytometry Data Analysis template, QuickCal®, is designed to work with all Quantum™ Simply Cellular® Kits (access QuickCal® by visiting www.bangslabs.com/products/quickcal and entering the Access Number provided with your standards).

  9. Quantum™ APC MESF | Polysciences, Inc.
    Quantum™ APC MESF
    Catalog Number BLI823A

    Quantitative MESF Kits consist of a series of reference microbead standards whose intensities have been calibrated in Molecules of Equivalent Soluble Fluorochrome (MESF) units. Our FREE Flow Cytometry Data Analysis template, QuickCal®, works with all Quantum™ MESF Kits (access QuickCal® by visiting www.bangslabs.com/products/quickcal and entering the Access Number provided with your standards).

    A test requires one drop (50μl, ~100,000 particles) of each particle suspension. Bangs Flow Cytometry Standards are 7-9μm in diameter (unless otherwise noted) to approximate the size of human lymphocytes.

  10. Size Calibration Standards | Polysciences, Inc.
    Quantum™ R-PE MESF
    Catalog Number BLI827A

    Quantitative MESF Kits consist of a series of reference microbead standards whose intensities have been calibrated in Molecules of Equivalent Soluble Fluorochrome (MESF) units. Our FREE Flow Cytometry Data Analysis template, QuickCal®, works with all Quantum™ MESF Kits (access QuickCal® by visiting www.bangslabs.com/products/quickcal and entering the Access Number provided with your standards).

    A test requires one drop (50μl, ~100,000 particles) of each particle suspension. Bangs Flow Cytometry Standards are 7-9μm in diameter (unless otherwise noted) to approximate the size of human lymphocytes.

  11. Quantum™ Simply Cellular® anti-Mouse IgG | Polysciences, Inc.

    Quantum™ Simply Cellular® Kits contain a mixture of microbeads which bind specific amounts of IgG antibodies. These standards are calibrated in terms of Antibody Binding Capacity (ABC) and can be used to construct calibration plots to determine the ABC of unknown samples and monitor instrument performance. Our FREE Flow Cytometry Data Analysis template, QuickCal®, is designed to work with all Quantum™ Simply Cellular® Kits (access QuickCal® by visiting www.bangslabs.com/products/quickcal and entering the Access Number provided with your standards).

  12. Quantum™ Alexa Fluor® 647 MESF | Polysciences, Inc.

    Quantitative MESF Kits consist of a series of reference microbead standards whose intensities have been calibrated in Molecules of Equivalent Soluble Fluorochrome (MESF) units. Our FREE Flow Cytometry Data Analysis template, QuickCal®, works with all Quantum™ MESF Kits (access QuickCal® by visiting www.bangslabs.com/products/quickcal and entering the Access Number provided with your standards).

Userway Icon